ELIMINATE UNPLANNED DOWNTIME WITH​

POWER THAT PROTECTS

Achieve greater uptime for your operations with Plug-&-Forget Voltage Regulating Solutions that deliver highly optimised, stabilised and constant voltage supplies.

To Our Valued Customers: Past, present & Future

We continue to serve, ensuring no interruptions to your operations.​ Keep your Ashley Edison equipment in pristine working conditions for years to come. Get the best results from your equipment and maximise your unit’s lifespan—by only choosing genuine and authentic Ashley Edison spare parts. 

ashley edison(UK)™ - Trusted By clients in all sectors

Projects by Ashley Edison

Discover how we’re helping consultants and facility managers like you to solve voltage challenges with robust solutions that meet your needs.

avr cost pays for itself
Secrets To How Your AVR Cost Is Actually Paying For Itself
automatic voltage regulators changed solar industry
How Automatic Voltage Regulators Changed The Solar Industry
voltage drop
RADIO TELEVISYEN MALAYSIA (RTM) & PT INDOSAT TBK
ashley edison automatic voltage regulator
Banyan Tree – Seychelles
Singapore Power – Transmission Cable Tunnel Project
coca cola
Coca-Cola – Saudi Arabia
voltage fluctuation ashley edison
Humber Bridge – U.K.
ashley edison variable transformer
TÜV SÜD – Singapore
mains voltage stabilisers
DEPARTMENT OF STATE
U.S. Embassy – Papua New Guinea
automatic voltage stabiliser voltage fluctuation
British Petroleum – Georgia
ashley edison
ARMY
Military-Grade Voltage Protection
voltage drop
ABB – Latvia

PRODUCT RANGE

Fully Customizable Voltage Regulating Solutions just for you.

OUR ACCREDITATIONS

Accreditiatons_0001_CE Mark
ISO 9001-2015
TUV SUD ISO Logo
Electrical professionals:

Up your voltage game.

Up your results.

Learn industry secrets and gain insider knowledge on how to easily overcome the most challenging voltage struggles - with one 11 min read at a time.

Topics such as:

ABOUT

1 Vision of Voltage Perfection

Ashley Edison serves to build you a better world with more robust voltage solutions that are safe, cost-efficient and sustainable. No operation is too big or small and we’re here to make sure it works for you.

1
YEARS OF EXPERIENCE
1
Industrial & Commercial Sites in Operation
1
Countries With Industrial Installations
Contact Us

Looking for lasting and dependable voltage protection? Or simply hunting for a quote? We’re here to solve that for you.

Get 24/7 personalised help from our international sales team for a customised solution that will meet your operational needs. Take the puzzle out of protection today.

Ashley Edison International Ltd​
Contacts

U.K. HEADQUARTERS
[email protected]
Tel: +44 (0)148 367 7998

ASIA PACIFIC HEADQUARTERS
[email protected]
Tel: +65 6339 9433

AU/NZ AUTHORISED DISTRIBUTOR
[email protected]

Mr. Len McKelvey

Tel: 1300 563 219
Mobile: 0415 585 616

Scroll to Top

Three Phase

SESL-H-3P-S Model
Large Capacity Rating
200 to 2,000 KVA

 

Enclosure 335
1000W x 1300H x 580D (mm)
250~300 KVA ± 15%
120~200 KVA ± 20%

 

Enclosure 336
1280W x 1480H x 660D (mm)
400 KVA ± 15%
250 KVA ± 20%

 

Enclosure 337H
1880W x 1950H x 880D (mm)
500 KVA ± 15%
300 KVA ± 20%

 

Enclosure 339
1470W x 1950H x 1340D (mm)
600 ~ 1,500 KVA ± 15%
400 ~ 1,000 KVA ± 20%
300 ~ 750 KVA ± 25%
300 ~ 600 KVA ± 30%

Three Phase

SES-H-3P-S Model
Added I/P Breaker Protection
60 to 1,000 KVA

 

Enclosure 333
490W x 800H x 990D (mm)
≤ 100 KVA ± 15%

 

Enclosure 334
540W x 900H x 1000D (mm)
120 – 150 KVA ± 15%

 

Enclosure 335
1000W x 1300H x 580D (mm)
180 – 300 KVA ± 15%
120 – 200 KVA ± 20%
120 – 150 KVA ± 25%

 

Enclosure 336H
1880W x 1480H x 660D (mm)
400 KVA ± 15%
250 KVA ± 20%
180 ~ 200 KVA ± 25%

 

Enclosure 337H
1880W x 1950H x 880D (mm)
500 KVA ± 15%
300 KVA ± 20%
250 KVA ± 25%

 

Enclosure 339H
2170W x 1950H x 1340D (mm)
600~1,000 KVA ± 15%
400~600 KVA ± 20%
300~400 KVA ± 25%

Single Phase

SES-H-S Model
Added I/P Breaker Protection
1 to 100 KVA

Enclosure 102
270W x 460H x 490D (mm)
≤ 20 KVA ± 30%
≤ 15 KVA ± 20%
≤ 10 KVA ± 25%
≤ 10 KVA ± 15%

Enclosure 103
400W x 580H x 500D (mm)
25 KVA ± 15%
20 KVA ± 20%
15 KVA ± 25%

Enclosure 332
380W x 670H x 780D (mm)
30 KVA ± 15%

Enclosure 333
490W x 800H x 990D (mm)
40 ~ 50 KVA ± 15%
25 ~ 30 KVA ± 20%
20 ~ 25 KVA ± 25%
15 ~ 20 KVA ± 30%

Enclosure 334
540W x 900H x 1000D (mm)
60 ~ 75 KVA ± 15%
40 ~60 KVA ± 20%
30 ~ 50 KVA ± 25%
25 ~ 40 KVA ± 30%

Stay Safe With Greater Protection

As safety is our utmost priority, Ashley Edison prepares for every scenario possible
—taking the puzzle out of your protection.

Designed And Engineered With Safety In Mind

We leave nothing to chance when it comes to larger capacity units (≥400KVA). By installing high-quality protective acrylic shields in front of live parts, we ensure the safety of your personnel at all times. For enhanced protection during installation, all distances between uninsulated metal parts, busbars, and cable sizes are compliant with IEC61439-1 and IEC 61439-2 guidelines.

Outfitted with fireproof cable trunking, this protective solution safeguards against long fire exposure even in hazardous areas and explosive atmospheres—providing maximum safety for mission critical applications.

Fuss-Free Installation. Seamless Operations.

To ensure ease of installation, Ashley Edison addresses the concerns of contractors and installers by keeping it simple.

Internal-AVR

ALL TERMINATION POINTS ARE MANUFACTURED FOR EASY ACCESS

We keep the installation process simple and streamlined by allowing sufficient working space for installers. Taking the nut and bolt intrusions into consideration, we ensure that the distance between the uninsulated metal parts, the busbars, and cable sizes are compliant with IEC61439-1 and IEC 61439-2 guidelines.

 

Even in units with larger capacities, all busbar terminals are clearly marked out, and well positioned in line for easy identification of individual input and output terminations. Installation of these terminations are similar to those practised in high voltage transformers.

Easy Maintenance

Annual Ocular Maintenance
Visual Inspection 230
#1

Conduct Visual Inspection On Voltmeter:

Ensure reading is set to your desired set output voltage value (e.g. 230V).

LED Status
#2

Ensure LED Status Indicators are at “Normal”.

Subtxt LogoAsset 62 RGB
#3

Visual Observation Of Variable Transformer Surface:

Use airbrush for dusty environments if necessary.

Subtxt LogoAsset 72 RGB
#4

Visual observation if carbon brush is not worn out.

Moving Motor
#5

Conduct visual inspection to check variable transformers are all regulating (moving).

AE-MBB-PCB-Card-dark

Accuracy. Beyond Imagination.

The digitally enhanced Ashley Edison MBB Card ensures pinpoint voltage stabilisation against the most erratic anomalies, allowing you to protect precious uptime, effortlessly. Harnessing ultra precision capabilities to produce some of the tightest output voltage tolerance available in the industry, the Ashley Edison MBB Card delivers ±0.5% voltage accuracy, enabling your load equipment to enjoy optimal voltage supplies, regardless of load change in your electrical system.

Expert Digital Control

Utilising the advantageous measurements of true RMS, the Ashley Edison MBB Card’s reads both perfect, sinusoidal waves, as well as complex, distorted non sinusoidal waves—up to 0.1V accuracy. Coupled with lightning fast response time of 1.5ms, this expert digital control feature equips your load with total voltage protection that is precise, continuous and ultra responsive.

AE Digital Control Display_230v

Universal Presettable Function

The Universal Presettable Function onboard the Ashley Edison MBB Card allows seamless control of your desired output voltage value on all 3 Phases—with just a touch of a button. This multifunctional feature enables each AVR to fully operate with just 1 card, instead of separate cards for each individual phase. Fitted LED Output Voltmeter Display and Alert Indicator better facilitates easy status monitoring while performing maintenance on your AVR.

AE MBB Card

Microcontroller Unit (MCU)

MicroController Unit (MCU) helps you to deliver high speed and reliable efficiency in the AVR’s operations with less heat generation and reduced power consumption. Used in Supercomputers, Surface Mount Technology (SMT) allows components in the Ashley Edison MBB Card to be aligned closer together, creating a more compact and lightweight end product. Additional safety wire-to-board feature establishes fail-proof connectivity between circuits—so you can work safely on your AVR.